Diagnostic Manual MAN-00183
MAXXIMO MINIVAN VX June 2012/Rev 1
The reproduction, translation, transmission, in part of or whole of the present document are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any
person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution. © 2012 Mahindra &
Mahindra Ltd.
16
ECU
P1912
Impermissible offset between the engine speed of level 2 and level
1
190
P1913
Error in the plausibility of the injection quantities
P1914
Error in the plausibility of the start of energizing angles
P1915
Error in the plausibility check of the ZFC energizing times.
P1916
Error in the plausibility of PoI2 efficiency.
P1917
Error in the PoI2 shut-off.
P1639
State of overrun detection
P1918
error due to injection quantity correction
P1919
plausibility error in rail pressure monitoring
P1670
Shut off request of injection cut off
192
P191A
Diagnostic fault check to report the error due to torque
comparison
193
P191B
Diagnosis rail pressure path limitation due to a functional control
unit monitoring
P191C
Diagnosis of lead path limitation forced by ECU monitoring level
2
P191D
Diagnosis quantity path limitation due to a functional control unit
monitoring
Coolant
temperature
output
P160A
coolant temperature output (on dash panel): No load
195
P160B
coolant temperature output (on dash panel): Excess temp.
P1608
coolant temperature output (on dash panel): Short circuit to battery
P1609
coolant temperature output (on dash panel): Short circuit to ground
Sensor supply
monitoring 1
P1644
Error in sensor supply voltage 1
199
Sensor supply
monitoring 2
P1646
Error in sensor supply voltage 2
210
Sensor supply
monitoring 3
P1648
Error in sensor supply voltage 3
216
VSS
P0503
Vehicle speed sensing exceeds the maximum vehicle speed
222
P0501
Vehicle speed not plausible with injection mass and engine speed