Diagnostic Manual MAN-00183
MAXXIMO MINIVAN VX June 2012/Rev 1
The reproduction, translation, transmission, in part of or whole of the present document are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any
person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution. © 2012 Mahindra &
Mahindra Ltd.
266
Insert the Demister
Blower relay in its
position
Turn ignition ON
Check voltage between
terminal 86 of Demister
Blower relay
connector and battery
ground
Is the voltage 12
Volts?
YES
NO
Step 3
Turn ignition OFF
Demister Blower Relay
REMOVED
ECU connector
DICONNECTED
Check continuity between
terminal 85 of Demister
Blower relay connector and
terminal 91 of ECU
connector.
Turn ignition OFF
Demister Blower Relay
DISCONNECTED
Check Demister Fuse (20A)
& replace if necessary
Check the wiring harness
between terminal 86 of
Demister Blower relay
connector and terminal 87 of
the ECU relay for
continuity
Repair / Replace wiring
harness if necessary
Does continuity
exist?
YES
Go to Step 4
Examine the open circuit
Repair / replace wiring
harness
Step 2