Diagnostic Manual MAN-00183
MAXXIMO MINIVAN VX June 2012/Rev 1
The reproduction, translation, transmission, in part of or whole of the present document are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any
person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution. © 2012 Mahindra &
Mahindra Ltd.
267
Note:
Demister switch check points:
After the switch ON operation the corresponding lamp indication in the Cluster is visible.
Check the voltage between pin no 1 of the switch and pin no 16 of IC.2F:16, the voltage is to
fluctuate between 0v and 12v in OFF and ON condition respectively.
Check Demister Blower
relay terminals for oxidation
/ damages. Replace if
necessary
Clear error codes and verify
Turn ignition OFF
Demister Blower relay
DISCONNECTED
Check the continuity
between terminal 30 of the
Demister Blower relay
connector and battery
Step 4
Does continuity
exists?
Examine the open circuit
Repair/Replace the wiring
harness
Clear error codes and verify
YES