MATTOC TRAVEL ADJUST MANUAL
4. Using the Maoc 8mm Thin Wall Socket,
turn the compression rod clockwise unl
compression rod is disengaged from the
casng threads.
4
5. Remove casng from the fork. It is
recommended that this be done over a
drain pan as there is semi-bath oil in the
lower legs that will be released when
casng is removed.
5
6. Aach shock pump to the air valve on
the compression rod and use the pressure
release buon to release all air pressure
from the fork. If your shock pump does not
have a pressure release on it you can use
a 3mm Allen wrench to depress the valve
core and release the air.
Air pressure must be released
prior to disassembly of the fork. Failure to
properly and fully release air pressure could
result in serious injury or death.