2-34
21 - HEATER CONTROL
A - FAN CONTROL
This 3-speed control allows the air to be ventilated through the air vents.
B - TEMPERATURE CONTROL
Allows the temperature inside the cab to be adjusted.
B1 - The fan pumps in the air at ambient temperature.
B2 - The fan pumps in warm air.
The intermediate positions allow the temperature to be adjusted.
21 - AIR CONDITIONING CONTROLS (OPTION AIR CONDITIONING)
(MT-X 625 COMFORT)
The air conditioning only works if the lift truck has been started up. When using your air conditioning unit
you must work with the cab closed off.
In winter: So as to ensure correct operation and complete efficiency of the air conditioning unit, start up
the compressor once a week, if only for a short spell, so as to lubricate the internal seals.
In cold weather: Warm the I.C. engine before switching on the compressor, so as to allow the coolant
that has collected in a liquid state at the lowest point of the compressor circuit to turn into gas under the
effect of the heat given off by the I.C. engine, as the compressor is liable to be damaged by coolant in a liquid
state.
If your air conditioning does not seem to be working correctly, have it examined by your dealer (see: 3 -
MAINTENANCE: F - EVERY 2000 HOURS OF SERVICE). Never try to repair any faults yourself.
A - FAN CONTROL
This 3-speed control allows the air to be ventilated through the air vents.
B - TEMPERATURE CONTROL
Allows the temperature inside the cab to be adjusted.
B1 - The fan pumps in cold air.
B2 - The fan pumps in warm air.
The intermediate positions allow the temperature to be adjusted.
C - AIR CONDITIONING CONTROL
This control with a pilot light allows the air conditioning unit to be switched on.
HEATING MODE
The controls must be adjusted in the following way:
C - Control with pilot light off.
B - At the required temperature.
A - At the desired speed: 1, 2 or 3.
CONDITIONED AIR MODE
The controls must be adjusted in the following way:
C - Control with pilot light on.
B - At the required temperature.
A - At the desired speed: 1, 2 or 3.
DEMISTING MODE
The controls must be adjusted in the following way:
C - Control with pilot light on.
B - At the required temperature.
A - At speed 3.
For optimum effectiveness, close the heating ventilators.
A
B1
B2
B
C
A
B1 B2
B
647421 (22/08/2017)
MT-X 625 Série 2-E3 + COMFORT