14000 SERVICE MANUAL ELECTRIC SYSTEM
3
Main Display
The basic components for the main display are the
Information screen, Diagnostic screens, Function Mode
screens, CAN Bus screen, Camera screens, and Pressure
Test and Calibration screens.
The appearance and function of each screen depends on the
screen level. Some screen levels show icons and/or data
boxes that can be selected to change parameters and/or to
enter different screen levels.
“Manitowoc” Screen
The initial view displayed at crane startup is the “Manitowoc”
screen, shown in Figure 3-6
. This screen displays the
following program items:
Model/Program Number (14000 FCN number
shown).
Con Number (009 000 000 008 shown).
Screen Program Number (GUI 2.007 shown).
Screen Prompts
Screen prompts can appear on a selected screen if a fault
condition exist or to prompt or confirm certain operator
actions when required by the system. Prompt descriptions
and icons are shown below.
The
RCL Display is selected by pressing
and holding the Confirm key, then key 1,
then releasing the Confirm key.
The Main Display is selected by pressing and holding
the Confirm key, then key 2, then releasing the Confirm
key.
Yellow alert symbol is displayed if a system fault
occurs. For more information, see the 14000
Operator Manual.
Engine prompt. For more information, see the
14000 Operator Manual.
Purple confirm prompt appears when the
operator must start certain test routines from the
screen and to confirm data when required.
Engine stopped symbol is displayed when
engine is stopped.
Remote control symbol is displayed when
remote control operation is selected.
Menu Screen
See Figure 3-7
The Menu screen is the base screen for the crane system.
All other screens must be entered from this screen. Exiting
from any screen will return to the Menu screen.
The Menu screen shows six screen icons:
Information Screen icon
Diagnostic Screen icon
Function Mode Screen icon
CAN Bus Screen icon
Camera Screen icon
Pressure Test and Calibration Screen icon
The Menu screen operates on one level only.
Use Select buttons to highlight icon that represents the
screen to be entered. Press the Enter button to go to
selected screen.
To return to Menu screen, press Exit button until Menu
screen appears.
FIGURE 3-6
14COM3-28
FIGURE 3-7
CAN Bus
Screen
Diagnostic
Screen
Camera
Screen
Function Mode
Screen
Pressure Test and
Calibration Screen
14COM3-27-2
Information
Screen

Table of Contents

Other manuals for Manitowoc 14000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 14000 and is the answer not in the manual?

Manitowoc 14000 Specifications

General IconGeneral
BrandManitowoc
Model14000
CategoryConstruction Equipment
LanguageEnglish

Related product manuals