Manitowoc Published 09-05-14, Control # 226-02 1-53
14000 SERVICE MANUAL INTRODUCTION
1
FIGURE 1-30
Suction
Manifold
Drum 1 Pump #2
Raise
Lower
350 psi
(24 bar)
.060
Equalizing
Line
Accessory
System
Pressure
Sender
X
Upper Accessory Valve
To Lower Accessory Valve
Load Equalizing
Valve 4,000 psi
(275 bar)
Gantry Cylinders Raise
3,500 psi (240 bar)
Load Equalizing
Valve 4,000 psi
(275 bar)
Gantry Cylinders Lower
3,500 psi (240 bar)
Suction
Manifold
Drum 1 Pump #2
Raise
Lower
350 psi
(24 bar)
.060
Equalizing
Line
Accessory
System
Pressure
Sender
X
Upper Accessory Valve
To Lower Accessory Valve
Pressure
Sender
Pressure
Sender
14CSM1-120
B
A
B
A
14CSM1-121
HS-24
HS-25
HS-24
HS-25