2 For Your Safety
Operating and Installation Instructions UL 14
When moving units on a base with casters while the combi oven is being cleaned, keep the following
hazards in mind and take the actions required in order to eliminate and/or minimize these hazards
Risk / hazard Where and in which situations will the
risk/hazard exist?
What to do
All the risks and hazards
listed below
When units are being moved on a base
with casters
Before moving the unit (to clean the
combi oven’s case or the floor, for
example), check to make sure that the
retaining element designed to limit
how much the base can move with the
unit is attached.
De-energize the unit before moving it
When moving the unit, make sure not
to roll over any connection lines (elec-
trical, gas, and water)
Pinch point hazard (for
multiple body parts)
When units are being moved on a base
with casters
Pay attention to the utility and hose
connections.
Use at least two people to move the
unit
Pinch point hazard (hand
and foot hazard)
When units are being moved on a base
with casters
Keep the unit doors shut
Risk of scalding posed by
hot wastewater
When units are being moved on a base
with casters
Let the units cool down
Immediately wipe or mop up any water
that has leaked
Wear appropriate protective clothing
Risk of scalding posed by
hot, liquid food
When units are being moved on a base
with casters
Do not move units if there is any food
still in them
Risk of electric shock
posed by live parts
When units are being moved on a base
with casters
Pay attention to the utility and hose
connections.
Gas explosion hazard
When units are being moved on a base
with casters
Pay attention to the gas supply line
Skin and eye irritation
hazard as a result of
contact with cleaning
agents
When units are being moved on a base
with casters
Make sure that the connections are
long enough
When moving the base, keep the
cleaning agent canisters closed
Trip hazard as a result of
utility and hose connec-
tions routed in the open
When cleaning behind units that have
been pulled forward
Exercise caution when performing
maintenance work
Fall hazard as a result of
floors being wet with
wastewater
When cleaning behind units that have
been pulled forward
In front of the unit
Immediately wipe or mop up any water
that has leaked
Make sure that the connections are
long enough
Fall hazard as a result of
floors being wet with
cleaning agents
When cleaning behind units that have
been pulled forward
In front of the unit
When moving the units, keep the clean-
ing agent canisters closed

Other manuals for Manitowoc convotherm 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc convotherm 4 and is the answer not in the manual?

Manitowoc convotherm 4 Specifications

General IconGeneral
BrandManitowoc
Modelconvotherm 4
CategoryKitchen Appliances
LanguageEnglish