Part Number STH042 3/14 57
Troubleshooting
Control Board Test Mode
NOTE: The ice damper/bin switch can be open or
closed and does not effect the operation of the test
mode.
To enter the test mode press and hold the test button
on the control board for 3 seconds. The control board
test mode performs the following functions for a 2
minute time period:
Energizes all control board relays
Energizes all control board lights
Energizes all touch pad control lights
After 2 minutes the control board will automatically
initiate and complete one ice making cycle, then stop.
Canceling a test cycle:
To cancel a test cycle press the test button a second
time.
Restarting a test cycle:
The test cycle will restart each time the test button is
pressed for a 3 second time period.
OPERATING ICE MACHINE WITH BIN AND TOUCH
PAD REMOVED.
The ice machine is designed to allow diagnostic
procedures to be performed with the bin removed. The
touch pad is attached to the bin and is disconnected
during the removal process. Use the control board test
mode to operate the ice machine without connecting
the touch pad.