EasyManuals Logo
Home>Manitowoc>Ice Maker>NEO

Manitowoc NEO User Manual

Manitowoc NEO
136 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
70 Part Number STH042 3/14
Determining Which Safety Limit Stopped
the
Ice Machine:
When a safety limit condition causes the ice machine
to stop, the safety limit light on the control board
continually flashes on and off.
CONTROL BOARD SAFETY LIMIT LIGHT
OPERATION, BEFORE THE POWER BUTTON HAS
BEEN CYCLED ON/OFF:
Watch the safety limit lights on the control board:
SL#1 flashes = 3 or more 60 minute cycles
SL#1 continuously on = 6 consecutive 60 minute
freeze cycles
SL#2 flashes = 3 consecutive 3.5 minute harvest
cycles
SL#2 continuously on = 100 consecutive 3.5
minute harvest cycles
SL#1 & SL#2 flash = SL#3, neither float opened
within 4 minutes of the freeze cycle.
CONTROL BOARD SAFETY LIMIT LIGHT
OPERATION USING THE POWER BUTTON:
1. Press the power button once.
2. Press the power button again to start ice making.
3. Watch the safety limit lights.
One will flash corresponding to safety limits 1 or 2.
4. Safety limit 3 is indicated by both SL#1 & SL#2
flashing.
After safety limit indication, the ice machine will restart
and run until a safety limit is exceeded again.
Safety Limit Notes
A continuous run of 100 harvests automatically
erases the safety limit code.
The control board will store and indicate only one
safety limit – the last one exceeded.
If the power button is cycled OFF and then ON
prior to reaching the 100-harvest point, the last
safety limit exceeded will be indicated.