Manitowoc NEO - Suction Pressure High Troubleshooting; Causes for High Suction Pressure Checklist

Manitowoc NEO
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Part Number STH042 3/14 79
Suction Pressure High Checklist
Improper Installation
• Refer to “Installation/Visual Inspection Checklist”
on page 64.
Discharge Pressure
• Discharge pressure is too high, and is affecting
suction pressure, refer to
“Discharge Pressure
High Checklist” on page 76.
Improper Refrigerant Charge
• Overcharged
• Wrong type of refrigerant
• Non-condensable in system
Other
• Non-Manitowoc components in system
• Harvest valve leaking
• TXV flooding (check bulb mounting)
• Defective compressor