CAUTION IN SERVICING
Initializing This Unit
Make sure to initialize this unit after replacing the microcomputer or any peripheral equipment, or the digital PCB.
1. Press the power button to turn off the power.
2. While holding down buttons "
ZONE2 SOURCE
" and "
INTERNET RADIO
" simultaneously, press the power button to
turn on the power.
3. Release the buttons after conrming that the display ashes at 1-second intervals.
The unit is initialized.
NOTE
• If the unit fails to enter the service mode in step 3, repeat the procedure from step 1.
Initializing the device restores the customized settings to the factory settings. Write down your settings in advance and
recongure the settings after initialization.
JIG FOR SERVICING
Use the following jigs (extension cable kit) when repairing the PCBs.
Order with your dealer for the jigs your dealer if necessary.
8U-110084S : EXTENSION UNIT KIT : 1Sets
8U-110136S : EXTENSION UNIT KIT : 1Sets
(See page 50)