9
To check if the amp is in order, switch off the unit and switch
it on again one minute later. This action will deactivate
the protection operation. If the PROT-1 (pin54) remains
“L”, which constitutes an abnormality, the unit shuts down
approximately 3 seconds later and the OPERATION
indicator starts flickering.
If the protection operation will not be deactivated after the
power is turned on again, the amp circuit may be broken.
[B] The PROT-2 (pin53) is the port to detect
abnormalities of the power supply circuit
Detection of an abnormality in the power amp power 1.
supply circuit.
This port monitors the midpoint voltage of the power amp
power supply between +58V and -58V. If the voltage at
the connection point of R809 and R810 exceeds DC
±1.2V, Q803 or Q804 will turn on to change the signal
from the PROT-2 (pin53) to L from H.
Detection of an abnormality in the preamp power supply 2.
circuit.
This port monitors the midpoint voltage between +30V
and -30V. If the voltage at the connection point of R813
and R814 exceeds DC ±1.2V, Q805 or Q806 will turn on
to change the signal from the PROT-2 (pin53) to L from H
Detection of an abnormality in the function relay power 3.
supply circuit.
If the +24VLB of the relay power supply receives an
electric current of over 120mA, Q809 and Q805 will turn
on to change the signal from the PORT-2 (pin53) to L
from H.
The Fuse (F851) inside the SOFT START PWB (P851) 4.
blows, the signal from the PROT-2 (pin53) terminal will be
changed to L from H.
If any of the above four abnormalities is detected, the signal
from the POW-1 (pin25) and POW-2 (pin24) changing to L
from H, the power relay L852 and L853 will be turned off
and the unit will be shut down. Then, the OPERATE indicator
flickers and indicates that an abnormality has occurred.
This protection operation is intended for a breakdown of the
AMP circuit or the power supply circuit and immediately shut
s off the power in order to avoid the risk of damage.
To check if the amp circuit or the power supply circuit is
broken, switch off the power and then switch it on again
one minute later. This action will deactivate the protection
operation.
If the RPOT-2 (pin53) remains L after the power is switched
on again, the unit will be shut down again three seconds
later with the OPERATE indicator flickering.
If the unit is powered on again and yet cannot get the
protection operation deactivated, the amp circuit or the
power supply circuit may be broken.
[B] PROT-2 (pin53)は、電源回路の異常を検出するポート
パワーアンプ用電源回路の異常を検出。1.
パワーアンプ用電源の+58V と-58Vの中点電圧を監視
し、R809とR810の接続点の電圧が約 ±1.2V (DC) を超
えると、Q803もしくはQ804がONしてPROT-2 (pin53)が
"H→L" になる。
プリアンプ用電源回路の異常を検出。2.
プリアンプ用電源の +30V と -30V の中点電圧を監視
し、R813とR814の接続点の電圧が約 ±1.2V (DC) を超え
ると、Q805もしくはQ806がONしてPROT-2 (pin53)が
"H→L" になる。
ファンクションリレー用電源回路の異常を検出。3.
リレー用電源の+24VLB に約120mAを超える電流が流れる
と、Q809, Q805がONしてPROT-2(pin53)が "H→L" にな
る。
F851 FUSE (SOFT START PWB P851)が切れている場4.
合、Q807がONし、PROT-2(pin53) が "H→L" になる。
1.〜4.のいずれかの異常を検出すると、POW-1 (pin25)と
POW-2 (pin24)を "H→L" にして、電源リレー L852とL853 を
OFFしシャットダウンします。このときOPERATEインジケー
ターが点滅し、異常が起きたことを表示します。
これは、アンプ回路もしくは電源回路の故障を想定した
PROTECTION動作で、危険回避のため即座に電源を切る動作
です。
アンプ回路もしくは電源回路が故障しているかどうかを確認す
るには、一旦電源SWを切り1分ほど待ってから電源SWを再投
入します。
この操作でPROTECTION動作が解除します。
電源SWを再投入してもPROT-2 (pin53)が "L" の異常状態の場
合は、約3秒後に再びシャットダウンしてOPERATEインジケ
ーターが点滅します。
電源を再投入してもPROTECTION動作が解除されない場合
は、アンプ回路もしくは電源回路が故障していると考えられま
す。