8
5. PROTECTION MODE
Explanation of microprocessor (QU01) [PROT-1 (pin54) and
PROT-2 (pin53)].
[A] The PROT-1(pin54) is the port to detect the following
abnormalities of the Power AMP
Detection of an abnormality in the DC offset voltage from 1.
the Speaker Output terminal.
If the voltage from the Speaker Output terminal exceeds
approximately 1.2V (DC), Q905 or Q906 will turn on and
the signal from the PROT-1 terminal will change to L from
H.
Detection of an abnormal current from the power 2.
transistors (Q628, Q629, Q728, Q729).
If an electric current of over 10A flows in Q628 or Q629,
Q630, Q631 and Q908 turn on, and the signal from the
PORT-1 terminal will change to L from H.
If an electric current of over 10A flows in Q728 or Q729,
Q730, Q731 and Q908 turn on, and the signal from the
PORT-1 terminal will change to L from H.
Detection of an abnormal temperature of the Heat Sink.3.
If the temperature of the Heat Sink exceeds
approximately +110 degrees C, the posistor (R659 and
R759) will turn on Q907 and the signal from the PROT-1
terminal will change to L from H.
If any of the above three abnormalities is detected, the signal
from the PROT-1 terminal will change to L from H, and the
protection circuit will be activated, the signal from the SPK_
OUT (pin40) changing to L from H and the speaker relays
L901 ~ L905 immediately turned off.
What this protection operation results in after this depends
on how long the signal from the PROT-1 has to remain L.
• IfthePROT-1(pin54)recoversto“H”withinasshorta
period of time as one second or less.
Themessage“PROTECT”flashesonthedisplay,
thereby indicates that the protection circuit has come
into operation and automatically turns down the volume.
The protection circuit is deactivated after approximately
8 seconds, so that readjusting the volume will allow
normal use of the unit again. This protection operation is
intended for the situation wherein the user has misused
the unit temporarily and automatically resets the unit
while the amp circuit is functioning properly.
• IfthePROT-1(pin54)remainsLformorethanone
second.
The amp will be powered off by the POW-1 (pin25) and
POW-2 (pin24) changing to L from H and Power relay
L852 and L853 turned off
Then, the OPERATION indicator flickers, thereby
indicating that an error has occurred. This protection
operation is intended for a failure in the amp circuit and
immediately turns the power off to avoid the risk of any
damage. Depending on how the user is handling the unit,
this operation may be performed no matter if the amp is
functioning properly.
5. PROTECTION動作について
マイコン(QU01)PROT-1 (pin54) PROT-2 (pin53)の説明。
[A] PROT-1(pin54)は、パワーアンプの下記の異常動作を検出
するポート
スピーカー出力端子のDCオフセット電圧の異常電圧を検1.
出。
スピーカー出力端子が約1.2V (DC) を超えるとQ905もしく
Q906ONして、PROT-1端子が "HL" になる。
パワートランジスタ(Q628, Q629, Q728, Q729)の異常電2.
流を検出。
Q628もしくはQ629に約10Aを超える電流が流れると
Q630, Q631, Q908ONして、PROT-1端子が "HL"
なる。
Q728もしくはQ729に約10Aを超える電流が流れると
Q730, Q731, Q908ONして、PROT-1端子が "HL"
なる。
ヒートシンクの異常温度を検出。3.
ヒートシンクの温度が約110℃を超えると、ポジスター
(R659, R759)によってQ907ONして、PROT-1端子が
"HL" になる。
1.3.のいずれかの異常検出でPROT-1端子が "HL" になると
保護回路が動作して
SPK_OUT (pin40) "HL" にして、即座にスピーカーリレ
L901L905OFFにします。
このPROTECTION動作はPROT-1端子が"L"になっている時間
によって、その後の動作が異なります。
PROT-1 (pin54)1秒以内の短時間の間に "H" に復帰した
場合。
ディスプレイ部に"PROTECT"の文字が点滅
し、PROTECTION動作になったことを知らせ、自動的に
ボリュームを下げます。
8秒後に保護回路が解除しますのでボリュームを再調整す
ればそのまま使用することができます。
これは、ユーザーが一時的に使用法を誤った場合を想定し
PROTECTION動作で、アンプ回路は故障していない場
合に自動復帰する動作です。
PROT-1 (pin54)1秒以上 "L" になっている場合。
POW-1 (pin25)POW-2 (pin24) "HL" にして、電源
リレー L852L853 OFFし、アンプの電源をシャットダ
ウンします。
このときOPERATEインジケーターが点滅し、異常が起き
たことを表示します。
これは、アンプ回路の故障を想定したPROTECTION動作
で、危険回避のため即座に電源を切る動作です。
ユーザーの使用状況によっては、アンプが故障していなく
てもこの状態になる可能性もあります。
アンプが故障しているかどうかを確認するには、一旦電源
SWを切り1分ほど待ってから電源SWを再投入します。
この操作でPROTECTION動作が解除します。
電源SWを再投入してもPROT-1 (pin54) "L" の異常状態
の場合は、約3秒後に再びシャットダウンしてOPERATE
ンジケーターが点滅します。
電源を再投入してもPROTECTION動作が解除されない場
合は、アンプ回路が故障していると考えられます。