Error
Code
DPMS Update Error
Display
Details of Error code Remedies
24
Error**24
DPMS connection failure
notiî™°cation after SBL.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
25
Error**25
Failed to transit to SBL Mode.
Unplug and reconnect the AC plug, and
try again.
26
Error**26
Error in Firmware Download
(Time Out).
Unplug and reconnect the AC plug, and
try again.
27
Error**27
Failed to write to EEPROM
after SBL Mode.
Unplug and reconnect the AC plug, and
try again.
36
Error**36
DPMS login incorrect notiî™°ca-
tion.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
38
Error**38
DPMS connection failure
notiî™°cation.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
39
Error**39
DPMS connection Time Out
Error.
Unplug and reconnect the AC plug, and
try again.
3A
Error**3A
Error(NG) notiî™°cation received
while requesting Firmware
Download.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
3C
Error**3C
Error(Connect failure) notiî™°ca-
tion received while request-
ing Firmware Download.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
3D
Error**3D
After SBL Mode IP Address
acquisition failure (AutoIP).
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
3E
Error**3E
After SBL Mode IP Address
acquisition failure (Time Out).
Unplug and reconnect the AC plug, and
try again.
3F
Error**3F
Failed to transit to SBL Mode.
Unplug and reconnect the AC plug, and
try again.
50
Error**50
DPMS login incorrect notiî™°ca-
tion.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
52
Error**52
DPMS connection failure
notiî™°cation.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
Error
Code
DPMS Update Error
Display
Details of Error code Remedies
54
Error**54
Error notiî™°cation received
while requesting the Firm-
ware Info.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
55
Error**55
Time Out while obtaining
Firmware information.
Unplug and reconnect the AC plug, and
try again.
56
Error**56
Error(NG) notiî™°cation received
while requesting Firmware
Download.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
58
Error**58
Error(Connect failure) notiî™°ca-
tion received while request-
ing Firmware Download.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
5A
Error**5A
Invalid Device ID in response
or no response from Sub for
the "C" command.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
5B
Error**5B
NACK received in response or
no response from Sub for the
"L" command.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
5C
Error**5C
No Update Packet received
from CY920 (Time Out).
Unplug and reconnect the AC plug, and
try again.
5D
Error**5D
Abnormal data in Update
Packet received from CY920
(CRC Error).
Unplug and reconnect the AC plug, and
try again.
5E
Error**5E
Abnormal data in Update
Packet received from CY920
(Packet No Error).
Unplug and reconnect the AC plug, and
try again.
5F
Error**5F
Setup failure of the XModem
transfer method.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
60
Error**60
NACK received in response or
no response from Sub for the
"P" command.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
61
Error**61
Mismatched Check Sum in
response or no response from
Sub for the "I" command.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
161
Caution in
servicing
Electrical Mechanical Repair Information Updating