4.9 WATER CONNECTIONS
- All pipes, pipe ttings, valves and other components, including soldering materials, must be
suitable for potable water systems.
- A manual shut off valve must be installed on the cold water inlet to the water heater between
the main water supply line and the water heater.
- Only a gate valve or a ball valve is to be used on the cold water supply.
- Check the cold water pressure. If above 1000 kPa an approved limiting valve must be tted.
- Before installing the water heater, ush the water line to remove all debris, and after installation
is complete, purge the air from the line. Failure to do so may cause damage to the heater.
- To prevent water heater water system damage caused by excessive pressure. At the water
outlet of the water heater, it is necessary to install an appropriate pressure relief valve to protect
the water system and user safety. The pressure relief valve complies with ANSIZ21.22/CSA 4.4
- In the hot water system, the temperature rises continuously, and the volume of water expands.
- If the system is equipped with an expansion tank or a exible connection bellows can absorb a
part of the expansion amount, the expansion tank or the soft connection bellows cannot absorb
the pressure relief valve needed to protect the pressure relief valve to protect The entire system
prevents breakage of pipes and other components, so the relief valve pressure setting is
generally selected to be slightly less than the maximum pressure (Pmax) that the entire system
can withstand.
- In addition, the pressure can not be the same as the normal operating pressure.
- In order to prevent the damage of the temperature probe or control system and cause the
continuous heating of hot water to reach 100ºC (212°F) vaporization, it is necessary to install a
temperature and pressure safety valve, and the temperature and pressure valve temperature
reaches 99ºC (210°F) to relieve the pressure, thereby protecting the entire system. So the safety
valve temperature is generally set to 99ºC (210°F).
- There is a wire mesh lter to discourage debris from entering your heater. Clean lter after
initial installation to ensure no debris from the pipe work has clogged it.
HOT WATER OUTLET
FILTER AND DRAIN PLUG
GATE OR BALL VALVE ON INLET
COLD WATER INLET
WATER OUTLET
TEE VALVE
PRESSURE RELIEF VALVE
DRAIN PIPE