REMOTE CONTROLLER INSTALLATION REQUIREMENTS
- The remote controllers are splash resistant, however should not be positioned where it can be
splashed directly & should be appropriately sealed between the surface of the wall & controller.
- The remote controller can be installed in the bathroom provided it is correctly installed.
Remote controllers output temperature setting (70°C mode)
- The remote controller is able to adjust the output temperature in the range of 95ºF to 158ºF in
one degree increments.
5.1 REMOTE CONTROLLER INSTALLATION
The remote controller comes with a 7.9m cable.
If a longer cable is needed, please purchase a
shielding line. Cut the original line and rewire
according to the polarity to avoid short circuit
whilst adhering to the requirements below:
a. Minimum 18AWG wire
b. Maximum run of 30m
- Attach the remote control to the wall with screws supplied.
- DO NOT locate the remote controls where they may come into contact with water.
- DO NOT position the remote controls in the vicinity of chemicals.
- DO NOT position the remote controls over a heat generating appliance (i.e. cooker, toaster)
- DO NOT position the remote controls where materials may spill onto them.
- PLEASE NOTE IF THE CONTROLS ARE TO BE FITTED TO A METAL SURFACE AN INSULATION
PLATE SHOULD BE PROVIDED BEHIND THE MOUNTING POSITION.