11
Metal Structure for Suspended Ceiling
Electrical Requirements
The 115VAC/230VAC service line for the ceiling light should be evaluated and installed by a
licensed electrician in accordance with local electrical codes.
We recommend that a wall switch be installed in the power supply to facilitate servicing
and protect the light transformer in the vent of power surges while the light is not in use (i.e
electrical storms).
3/8” BOLTS
SUSPENDED CEILING
COVER
LEVELING PLATE
FINISHED CEILING
USE METAL MASONRY ANCHOR
WHEN REQUIRED
STEEL PLATE
1/8” THICK
(6) 3/8” BOLTS
EACH BOLT MUST SUPPORT
AT LEAST 75 LBS.
1-1/2” x 3/4” x 1/8” CHANNELS
WELDED TO PLATE
FIGURE 7