Do you have a question about the Masibust VT7S12E and is the answer not in the manual?
Brand | Masibust |
---|---|
Model | VT7S12E |
Category | Transmitter |
Language | English |
Instructions for connecting wires to the controller before installation.
Details on various input types like Accelerometer, RTD, RPM, and Linear inputs.
Specifies voltage range and power consumption of the device.
Information about the device's display, keys, and scan time.
Details on mounting, dimensions, material, weight, and terminal size.
Specifies ambient temperature, humidity, and storage conditions.
Details on the number, purpose, and rating of output relays.
Information on analog output signal types, load resistance, and accuracy.
Details on communication port, protocol, baud rate, and error detection.
Specifications for buffer output impedance, frequency range, and accuracy.
Details on isolation ratings and signal isolation between terminals.
Used to enter submenus and save parameters, facilitating configuration.
Used to exit submenus to run mode or manual to auto mode.
Increments parameters and can switch between Auto/Manual modes.
Shifts digits for parameter setting and acknowledges trip relays.
Visual representation of the main menu navigation and parameter flow.
Details and descriptions of various menu parameters available for configuration.
Configuration options for relay groups, types, and logic.
Defines how relay contacts change state based on Normal or Fail Safe logic.
Sets relay function to ALARM or TRIP for abnormal conditions.
Allows setting a time delay for the actual relay output.
Enables selection of upscale or downscale for open sensor detection.
Refers to Menu layout LEVEL - 2 for relay mapping configuration.
Describes various relay operations and selection methods.
Explains ON/OFF control logic and hysteresis for temperature control.
Steps for calibrating the zero and span of PV input sensors.
Procedure for calibrating zero and span for analog retransmission outputs.
Lists Modbus function codes and their corresponding uses.
Details Modbus exception response codes and their meanings.
Table listing Modbus parameters for process values with addresses and types.
Table showing Modbus values for abnormal input conditions.
Comprehensive table of Modbus parameters for input registers and their configurations.
Details Modbus parameters used for calibration register settings.
Lists Modbus parameters for reading output status registers.
Explains how PV input status is displayed during burnout conditions.