DIGITAL MULTIMETER
SPECIFICATIONS
- Voltage Drop200µA20mA2A: 20mV,
2000µA200mA10A range: 200mV
3.2.5 DC Current with clamp, optional
Range Resolution Accuracy
meter
200A
0.1mV/0.1A ±1.2 % of rdg + 3 digits
DC Clamp
0 to 200A
0.1A /0.1mV Typical ±2.0 %
meter
2000A
1mV/1A ±1.2 % of rdg + 3 digits
DC Clamp
0 to 2000A
1A/1mV Typical ±2.0 %
- Overload Protection: 250V DC or AC rms
- Max. Input Voltage: 200mV
3.2.6 AC Current with clamp, optional
Range Resolution Accuracy
meter
200A
0.1mV/0.1A ±1.5 % of rdg + 5digits
AC Clamp
0 to 200A
0.1A/0.1mV Typical ±3.0 %
meter
2000A
1mV/1A ±1.5 % of rdg + 5 digits
AC Clamp
0 to 2000A
1A/1mV Typical ±3.0 %
- Overload Protection: 250V DC or AC rms
- Max. Input Voltage: 200mV
- Frequency Range: 40 to 400Hz
- Response: Average, calibrated in rms of sine wave.
3.2.7 Continuity
Range Function
Built-in buzzer will sound, if resistance is
lower than 50.