EasyManua.ls Logo

Mastech MS8221C - Page 14

Mastech MS8221C
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
DIGITAL MULTIMETER
SPECIFICATIONS
- Open circuit voltage: approx. 0.5V
- Overload Protection: 250V DC or AC rms
3.2.8 Resistance
Range Resolution Accuracy
200Ω 0.1Ω ±(1.0% of rdg + 3 digits)
2kΩ 0.001kΩ
20kΩ 0.01kΩ ±(1.0% of rdg + 1 digit)
200kΩ 0.1kΩ
2MΩ 0.001MΩ
20MΩ 0.01MΩ ±(1.0% of rdg + 5 digits)
- Open Circuit Voltage: 0.25V
- Overload Protection: 250V DC or AC rms
3.2.9 Temperature
Range -20℃ to 1000℃
Resolution 1℃
-20℃ to 0℃ ±(5% of rdg + 4digits)
Accuracy 0℃ to 400℃ ±(1% of rdg + 3digits)
400℃ to 1000℃ ±(2% of rdg + 3digits)
Range 0℉ to 1800℉
Resolution 1℉
0℉ to 50℉ ±(5% of rdg + 4digits)
Accuracy 50℉ to 750℉ ±(1% of rdg + 3digits)
750℉ to 1800℉ ±(2% of rdg + 3digits)
- Overload Protection: 250V DC or AC rms
- 11 -