MASTER CHEF
®
12˝ TABLETOP GAS PIZZA OVEN
13
REGULATOR FLOW LIMITING RESET
PRESSURE REGULATOR
If you are experiencing any of the following performance issues with your MASTER Chef
®
12˝ Tabletop Gas Pizza Oven:
• Burners not getting hot enough
• Low or incomplete burner flames
• Low gas pressure
• Burners not staying lit
FOLLOW THESE REGULATOR RESET INSTRUCTIONS:
1. Ensure the control knob is “0”/ OFF.
2. Ensure the LP cylinder valve is CLOSED.
3. Disconnect the regulator from the 20 lb LP cylinder.
4. Push in and turn the control knob counter-clockwise to the “MAX”
position. Let stand for 1-2 minutes, allowing all excess gas in the valve
to dissipate.
5. Push in and turn the control knob clockwise, back to the “0” / OFF
position.
6. Reconnect the regulator to the LP cylinder, as shown on page 12. Be
careful not to cross thread the connection. Hand-tighten only.
7. Check all connections. Perform a leak test. See Page 14.
8. Slowly open the LP cylinder and wait 5 seconds for the pressure to
stabilize.
9. Push in and slowly turn the control knob counter-clockwise to the “MAX”
position. A “click” will be heard when the ignition is activated. Continue
to HOLD the control knob for 5 SECONDS after ignition before releasing
the knob.
NOTE: IF IGNITION FAILS, TURN THE CONTROL KNOB BACK TO “0”/OFF AND REPEAT STEP 9, OR FOLLOW THE MATCH LIGHTING INSTRUCTIONS ON PAGE 15.
Avoid activating the flow limiting feature by following the proper lighting and shut down procedures and leak testing the system regularly.