1.
CONTINUITY
OPERATING INSTRUCTIONS
USING RELATIVE MODE
Relative mode is available in some functions. Selecting relative mode
causes the meter to store the present reading as a reference for
subsequent measurements.
Press the "REL" button. The meter enters Relative mode and
stores the present reading as a reference for subsequent
measurements. The symbol "REL" appears as an indicator and
the display reads zero.
Range
The built-in buzzer will sound if the resistance
is less than about 20 .
The buzzer may or may not sound if the
resistance is between 20 and 150 .
The buzzer will not sound if the resistance is
more than 150 .
Description
DIODE
Range
The display shows the
approx. forward voltage
drop of the diode.
Open Circuit Voltage:
about 3 V
Test Current: about 0.8 mA
Description Remark
18