Alpha Pro charge regulator – User and Installation Manual
An event by the Alpha Pro charge regulator that
triggers an action on another device in the
MasterBus network.
The device that should act due to the Alpha Pro
charge regulator event.
Selectable targets are system
dependent.
Action to be taken by the target device.
See Event target list in manual
of the selected device.
Data is linked to the command. See also Figure 18.
Off, On, Copy, Copy Invert,
Toggle.
Input is a pulse followed by a longer signal (1/0).
On changes the status to On at the first signal.
Off changes the status to Off at the first signal.
Copy lets the status follow the input.
Copy Invert lets the status follow the opposite of the
input.
Toggle changes the status at the first signal and back
at the second signal. It is often used in combination
with a pulse switch.
Figure 18: Event data
6.3.6 Event source list (Alpha Pro as event source)
The charging process switches to Bulk phase
The charging process switches to Absorption phase
The charging process switches to Float phase
The alternator number of revs reaches a certain level, based on the alternator shaft revs
Low field current alarm has been triggered
6.3.7 Event target list (Alpha Pro as event target)
The charging process switches to Bulk phase
The charging process switches to Absorption phase
The charging process switches to Float phase
This event pauses the charging process and forces the field current to 0%. This event is
used in combination with the stop charge event of Lithium-ion batteries. When charging
can be resumed, the process continues from this point forward.