EasyManua.ls Logo

Mastervolt CombiMaster 12V/3000W 160A - 3.4 Unit Protections

Mastervolt CombiMaster 12V/3000W 160A
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
3.3 Remote control
The CombiMaster Inverter/Charger can be monitored from a remote panel like the SmartRemote or a
Touch 5 (in a CZone network). Some settings can only be adjusted from a laptop/notebook or PC
connected to the CombiMaster Inverter/Charger via a USB Interface.
3.4 Protection
Overload or short circuit; while in the inverter mode, the CombiMaster Inverter/Charger will shut
down after 5 seconds of 200% overload or after 10 seconds 150%.
Transfer switch overload; the transfer switch of the CombiMaster Inverter/Charger is protected
against overload and short circuit. When the current through the transfer switch of the CombiMaster
Inverter/Charger is too high, the thermal fuse (item 8 on page 7) will disconnect the AC input.
High temperature; if the ambient temperature of the CombiMaster Inverter/Charger exceeds 104°F
[40°C], it will reduce power. If it exceeds 140°F [60°C], it will shut down, trigger the status LEDs and
optionally a remote alarm. As soon as the temperature drops below the factory default threshold,
the inverter is powered up automatically or the charger resumes its charge current.
Battery low/high; the CombiMaster Inverter/Charger can warn for low or high battery voltages by
triggering status LEDs and CZone/MasterBus alarms.
CAUTION!
The CombiMaster Inverter/Charger is not protected against:
- serious over voltage on the AC input;
- serious continuous overload on the AC output.
Make sure AC input is within the range of 90-135V
AC
and the continuous load connected to
AC OUT never exceeds 40A.
See section 6.2 on page 26 for an overview of the status LEDs. See chapter 5 on page 19 for the
required settings.

Related product manuals