1) SYMPTOM:
No resistance
2) SOLUTION:
1) Check the power resistance wire connection between the power resistor and LCB (Figure A).
2) Check the resistance value of the wiring coming out of the resistor (Figure A).
--If the resistance value is under 8 ohms, replace the power resistor.
--If the resistance value is over 8 ohms, replace the LCB.