21
8.6 01A8 / 02B6 / 02B7 / 02B8 ERROR TROUBLESHOOTING
ERROR MESSAGE 01A8 / 02B6 / 02B7 / 02B8
1) sYmPtom:
a. 01AB - Motor over current.
b. 02B6 - Speed up is overcurrent.
c. 02B7 - Speed down is overcurrent.
d. 02B8 - Running status is overcurrent.
2) solution:
a. Check the condition of the running deck and belt. Replace the belt and flip or replace the running deck as needed.
b. Replace the MCB.
8.7 01AD ERROR TROUBLESHOOTING
ERROR MESSAGE 0X029F
1) sYmPtom:
a. Motor over temperature.
2) solution:
a. Check the connection of the motor cable at the MCB (Figure A).
b. Use a multi-meter to check the motor wire circuit. Set the multi-meter to Ohms and place both terminals on the blue wires of the
motor cable (Figure B). There should be an Ohm reading of 0. If there is an Ohm reading above 0, replace the motor. If the Ohm reading is 0,
replace the MCB.
FIGURE BFIGURE A