24
8.12 TROUBLESHOOTING - NO POWER TO THE CONSOLE
1) SYMPTOM:
a. The unit is not getting power from the outlet.
b. The MCB is not getting power from the power receptacle.
c. The power switch and MCB LEDs are lit, but there is no power to the console.
2) SOLUTION:
a. Check to see if the power switch is lit. If it is not, plug the power cord into a known working outlet and re-test.
- If the power switch is still not lit, replace the power switch, receptacle, and / or the power cord.
b. Remove the motor cover and check to see if LED +12V (DSP4) is lit on the MCB (Figure A).
- If the LED +12V is not lit, check the incoming AC voltage to the MCB.
-ReplacetheMCBifallpowercomponentsareOK,andthereisACvoltstotheMCB.
c. If LED +12V is lit, check the connection of the console communication cable.
- If the console communication cable is connected correctly, please check the console cable for +12VDC (Figure B).
- If there is not power through the console cable to the console UCB , replace the console communication cable.
- If there is power through the console cable to the console UCB, but there is still no power on the console, replace the console.
FIGURE A FIGURE B
POWER SWITCH IS ON, BUT THE CONSOLE HAS NO DISPLAY