Chapter 6 Maintenance
- 45 -
Maintenance item Description
Confirmation of
temperature
Confirm whether the dry temperature and regeneration temperature
are controlled at the setting temperature of controller.
<Confirming method>
In case of dry temperature
1. After pushing the SV switch of the controller once, do theSV
indicator light up and confirm a setting value with dry temperature.
2. Pressing SV switch, do display the dry temperature and compare it
with the setting value.
3. If the setting value is a degree as±23, the dry temperature is
normal.
In case of regeneration temperature
1. Perform display the dry temperature on the controller indicator.
2. Press RESET and SV switches at the same time.
During a switch is pushed, the actual temperature of regeneration
side is displayed on the indicator.
3. If the regeneration temperature is a degree as 180220, it is
normal.
At the temperature around, it changes in the temperature but it is
not in the malfunction condition.