Chapter 7 Alarms Function
- 51 -
Alarm
indicator
Character
indicator
Malfunction contents/Interlock
Measure
Regeneration
sensor
broken
E6
When wiring for the
thermocouple (CA sensor)
and the thermocouple for the
dryness are broken.
The operation stops
automatically.
Refer to CHAPTER 8.
Troubleshooting and restore
extraordinary occurrence
cause.
↓
When pushing a Reset switch
after cancellation of the
malfunction cause, the
character indicator turns off.
No.1 Convey
Malfunction
E7※
No.2 Convey
Malfunction
E8※
No.3 Convey
Malfunction
E9
※
Over-temperature
alarm (external
signal)
E10 When the temperature within
the heating case is higher
than the set value of the
thermostat, the faceplate will
show such kind of alarm.
Refer to Chapter 8, the reasons
and handle when abnormity. If
need to release from the alarm
in force, please press the
Reset key, and the alarm
display on the faceplate will
disappear automatically.
※The device will not display the symbol with.