Maximum Controls MAX 2200 - ADJUSTMENTS; Open and Close Limit Setup

Default Icon
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
MOTOR
ON-LINE
LIMIT
SWITCH
ON-LINE
24V
GND
UL ALARM 12V
ALARM RET
RESET
GND
GATE
TAMPER
MAG
LOCK
OPEN
RIGHT
OPEN
LEFT
MAGLOCK
DELAY
PRIMARY
GATE
SAFETYCENTEREXIT
OPEN
MAX
GATE SPEED
STOP CLOSE
ANTI
TAILGATE
CLOSE TIMER
POSITION
RECORDER
ID
PLUG
AUTOMATIC OPEN/CLOSE CONTROLS
BATTERY
BACK-UP MODE
MATRIX 1
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
OPEN
COM
CLOSE
Tamper NO
COM
GND
Tamper IN
OFF
OFFON
EXIT
PARTIAL
OPEN
OBD PORT
BLACK BOX
MOTOR MOTION
CENTER
REVERSE SENSITIVITY
MOTOR OVERLOAD
NO LIMIT SWITCH /
CLAMP SLIPPING
MIN
MAX
12VDC
GND
24VDC
GND
MAX
MIN
OFF
SAFETY
LEAVE
OPEN
LEAVE
CLOSED
MADE in USA
OPEN
1 TIME
2Sec1.5Sec
COM
NC
BATTERY
IN USE
POWER
GATE
STATUS
(+)
GND
(-)
PRIMARY
GATE
(+)
GND
(-)
SEC
GATE
UL
ENTRAP
PHOTOCELL
GND
STRIKE
GND
KEYPAD / RDR
GND
FIRE DEPT
GND
MAX OPEN
GND
RADIO SIG.
RADIO GND
OPEN
STOP
CLOSE
COM
GATE DISABLE
Gate
Tamper
Relay
matrix 1
gate shut-off switch
This factory installed switch will disable the normal opening
devices when turned ON, such as keypad, exit loop etc. Only
the Jog Left or Jog Right buttons on the MAX MC-200 motor
controller will operate gate when Gate Shut-Off switch is ON.
This feature is useful when the gate operator is being serviced.
The gate operator can not accidentally get activated while this
switch is ON.
IMPORTANT: When the Gate Shut-Off switch is turned ON,
operator will be disabled and it will “BEEP” for a few
seconds to indicate that Gate Shut-Off switch is ON.
Dropping the Chain
If an existing alarm system (Building alarm system) is connected to the GATE TAMPER relay, notify proper authorities BEFORE
dropping the chain.
IMPROPER Dropping of Chain (Vandalize):
Gate Shut-Off switch is NOT turned ON.
When the chain is improperly dropped (Vandalized), the
OPERATOR ALARM and GATE TAMPER relay will activate.
The operator will shut down all operating functions.
The alarm reset button MUST be pressed to turn OFF the
alarm and reset the operator. If GATE TAMPER relay is
connected to an existing building alarm system, then they
will get a triggering of their alarm system and should be
notified of the situation.
PROPER Dropping of Chain (Normal Operator Servicing):
1. Turn Gate Shut-Off switch ON to disable operator alarm.
2. Drop the Chain.
3. GATE TAMPER relay WILL be activated.
4. Service operator.
5. Reconnect the chain to gate.
5. Turn Gate Shut-Off switch OFF.
6. Rearm an alarm system that may be connected
to the GATE TAMPER relay.
MAX MC-200 motor controller
PhotoCell
Edge
UL
Entrap
1
2
Limit SW
ON-LINE
MATRIX
JOG
JOG
LEFT
RIGHT
Jog LT
Jog RT
GND
Edge 1
Edge 2
Photo
Cell
ERD
Motor
OverLoad
POWER
MC-200
Motor Controller
16
15
14
13
12
3
4
5
MAX
LED ON
Sensitivity
Edge
ERD
Gate Shut-Off Switch
Alarm Reset Button
ON
OFF
Gate
Shut-Off
ON
OFF
Gate
Shut-Off

Table of Contents

Other manuals for Maximum Controls MAX 2200

Related product manuals