10
STANDARD CONTROL LOCATIONS
GROUND ACCESS - COLUMN SWITCH
Toggle switches on column switch (FIG. 10-1A)
let operator raise (UP), lower (DOWN), FOLD,
and UNFOLD the platform (FIG. 10-1B) while
standing on the ground.
PLATFORM ACCESS - RUNNER SWITCH
Toggle switch (FIG. 10-2A) on RH runner
lets operator raise (UP) and lower (DOWN) the
platform (FIG. 10-2B) only. Switch stays within
reach when operator rides platform UP and
DOWN.
FIG. 10-1B
FIG. 10-2B
FIG. 10-1A
FIG. 10-2A