Intelimax+4G User Manual
- 93 -
CPU, in which case AT$$TPSW=1 should be configured. After each configuration save
and reboot using AT&W and AT$$RESET.
AT$$TPSW=0 – Triple-plus switching handled by internal module
AT$$TPSW=1 – Triple-plus switching handled by the modem
Serial Port Settings
The follow AT commands are supported in both IP and Serial Modem modes to change
the serial baud rate and flow control:
Baud Rate: AT+IPR
AT+IPR=9600
OK
Flow Control: AT+IFC
AT+IFC=0,0 - no flow control
OK
AT+IFC=2,2 - hardware flow control
OK
CSD and PSD/PPP dial out commands (Serial mode only)
phone_number:
for Packet Switched Data: *99# (Australia – requires authentication)
for Circuit Switched Data: You will need a data number ( Code 2620
activated on the SIM account)
CONNECT (Data call connected)
CONNECT <SPEED> if connect_baud is
enabled. NO CARRIER (Data call failure)