EasyManua.ls Logo

Maxon MULTIMAX MA 2040 - Specifications

Maxon MULTIMAX MA 2040
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
!
!
!
!
12(
MULTIMAX(USER(GUIDE!
!
1.3 Specifications
Cellular Interface
! Standards: GSM/GPRS/EDGE/UMTS/HSPA/FDD LTE
! GPRS/EDGE: 850/900/1800/1900 MHz
! HSUPA: 900/2100 or 850/1900 MHz optional, DL/UL 7.2/5.76 Mbps, fallback to 2G
! HSPA+: 850/900/1900/2100 or 900/2100 or 850/1900 MHz optional, DL/UL 14.4/5.76 Mbps,
fallback to 2G
! FDD LTE: 800/900/1800/2100/2600 MHz or 700 MHz (B17 or B13) optional, DL/UL 100/50 Mbps,
fallback to 3G/2G
! SIM: 2 x (3V & 1.8V)
! Antenna Interface: SMA Female, 50 ohms impedance
Ethernet Interface
! Number of Ports: 2 x 10/100 Mbps, 2 LANs or 1 LAN 1 WAN
! Magnet Isolation Protection: 1.5KV
Serial Interface
! Number of Ports: 1 x RS-232, 1 x RS-485
! ESD Protection: 15KV
! Parameters: 8E1, 8O1, 8N1, 8N2, 7E2, 7O2, 7N2, 7E1
! Baud Rate: 2000bps to 115200bps
! Flow Control: RTS/CTS, XON/XOFF
! RS-232: TxD, RxD, RTS, CTS, GND
! RS-485: Data+ (A), Data- (B), GND
! Interface: 3.5mm terminal block with lock
Digital Input
! Type: 2 x DI, Dry Contact
! Dry Contact: On: short to GND, Off: open
! Isolation: 3K VDC or 2K Vrms
! Digital Filtering Time Interval: Software selectable
! Over-voltage Protection: 36 VDC
! Interface: 3.5mm terminal block with lock
Digital Output
! Type: 2 x DO, Sink
! Over-voltage Protection: 40 VDC
! Over-current Protection: 0.5 A
! Isolation: 3K VDC or 2K Vrms
! Interface: 3.5mm terminal block with lock