EasyManua.ls Logo

Maxon MULTIMAX MA 2040 - Configuration -> Serial

Maxon MULTIMAX MA 2040
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
!
MULTIMAX(USER(GUIDE(
63!
!
View
View @ SNMP
Item
Description
Defa
ult
View Name
Enter the View Name
Null
View Filter
Select from “Include” and “Exclude”.
Inclu
de
View OID
Enter the Object Identifiers (OID)
Null
VACM
VACM @ SNMP
Item
Description
Default
Readwrite
Select the access rights from “Readonly” and “ReadWrite”.
Readonly
Network
Define the network from which is allowed to access. E.g. 172.16.0.0.
Null
Community
Enter the community name.
Null
MIBview
Select from “none”, “system” and “all”
none
3.21 Configuration -> Serial
This section allows users to set the serial parameters.
RS232
RS232 @ Serial
Item
Description
Default
Baudrate
Select from “300”, “600”, “1200”, “2400”, “4800”, “9600”,
“19200”, “38400”, “57600” , “115200”and “230400”.
115200
Data bit
Select from “7” and “8”.
8
Parity
Select from “None”, “Odd” and “Even”.
None
Stop bit
Select from “1” and “2”.
1