Delimiter1/2 (Hex)
@Transparent
Enter the delimiter in Hex.
Delimiter Process
@Transparent
The Delimiter process field determines how the data is handled
when a delimiter is received.
None: Data in the buffer will be transmitted when the delimiter
is received; the data also includes the delimiter characters.
Strip: Data in the buffer is first stripped of the delimiter before
being transmitted.
Enter the Local port for Modbus.
Attached serial
device type
@Modbus
Select From “Modbus RTU slave”, “Modbus ASCⅡ slave”,
“Modbus RTU master” and “Modbus ASCⅡ master”.
Modbus RTU slave: router connects to slave device which works
under Modbus RTU protocol.
Modbus ASCⅡ slave: router connects to slave device which
works under Modbus ASCⅡprotocol.
Modbus RTU master: router connects to master device which
works under Modbus RTU protocol.
Modbus ASCⅡ master: router connects to master device which
works under Modbus ASCⅡ protocol.
Add the Modbus slaves which will be polled by Modbus master
(router). This section only displayed when you select “Modbus
RTU master” or “Modbus ASCⅡ master” in “Attached serial
device type”.
This connection is usually used to connect to the Modbus slave
devices which as TCP server. Enter IP address of the TCP server.
Enter the port number of TCP server.
Enter the ID number of TCP server.