Protocol: select the “mode” the serial connection should use:
UDP (DTU) use UDP, also send “Device number” and heartbeat
PURE UDP use UDP, no device numbers
TCP (DTU) use TCP (client), also send “Device Number” and “Device ID” and heartbeat
PURE TCP use TCP (client)
TCP Server use TCP (server)
TCST use TCP with additional custom data
Modbus TCP act as a Modbus TCP to serial gateway
NOTE: When in Modbus TCP mode, digital I/O pins can be read/controlled by either SMS or
Modbus on a pin by pin basis. Modbus address is fully configurable.
Server Address/Server Port/Listen Port: you can configure the server IP/Port to connect to here
(“server…” parts) or the port to listen on (“Listen Port”)
Device Number/ Device ID: Custom additional data in standard format
maXconnect
maXconnectsettings
maXconnet is device management portal. It is a cloud based M2M management
portal which allows you to access, monitor and control 3G/4G Maxon devices
securely. With maXconnect you can access real-time data from your devices,
monitor their status and location. Utilize complete functionality by controlling your
devices anywhere, anytime. This one stop portal is an access point to manage
your 3G/4G assets securely and remotely.
maXconnect can be used when the device is connected to the Internet or within
maXwan. When an Internet connection is used, the updates should go to
portal.maxconnect.com.au and the ftp from updates.maxconnect.com.au. When
using maXwan the updates should go to 10.0.0.1 and the ftp updates from
10.0.0.32. This feature is enable by default in firmware 3.0.2 or later.