PAGE 5
Service Diagnostics
Verification Cycle Execution
When Service Diagnostics Verification Cycle
is activated, any function(s) that were manually
commanded on will be turned off. Service
Service Diagnostics Verification Cycle Chart
Washer Recommended Est. Time
Display Function Procedure In Seconds
001 Warm water If no water, use Service Test Mode 10
fills through the to manually turn on and test the valve.
Detergent valve See page 4.
002 Cold water fills If no water, use Service Test Mode 10
through the Fabric to manually turn on and test the valve.
Softener valve See page 4.
003 Hot water fills If no water, use Service Test Mode 10
through the to manually turn on and test the valve.
Bleach/Oxi valve* See page 4.
004 Warm water If no water, use Service Test Mode 50–70
fills through the to manually turn on and test the valve.
detergent valve See page 4.
to minimum
water level
005 Validates pressure If this step fails, replace the Up to 5
sensor machine control.
006 Validates inlet If this step fails, go to and complete Up to 5
thermistor Test #5: Temperature Thermistor,
page 18.
007 Validates IPM If this step fails, replace the Up to 5
thermistor machine control.
008 Turns on heater* If heater does not turn on, use 8
Service Test Mode to manually turn
on and test the heater. See page 4.
009 Recirculates* If water is not being recirculated, 10
for 10 seconds use Service Test Mode to test
the recirculation pump. See page 4.
010 Skip N/A –
011 Lid will lock Lid must be closed. If lid does not 10
lock, use Service Test Mode to manually
test the lid lock. See page 4.
012 Skip N/A –
013 Drain pump on If water is not draining, use Service Test 20
for 15 seconds Mode to test the drain pump. See page 4.
* On models without bleach/oxi valve, heater, and/or recirculation pump, steps 3, 8, and 9
will be skipped.
Diagnostics Verification Cycle will start and
the step number within the Service Diagnostics
Verification Cycle sequence will be shown on
the display. NOTE: The basket must be empty
during this test.