McCONNEL MULTIDRIVEM380‐4&M420‐4
34
PTO setup
To alter parameters scroll up and down using the arrow keys on the left hand side to select
the parameter to be adjusted then use the right hand keys to adjust the figures up/down.
Press Save & return to save the settings.
The PTO settings are pre-set at the factory and do not normally require adjustment unless
the machine is being used for some other purpose. Most of the parameters are self-
explanatory other than the last one:
Maximum PTO 1 PWM output %
This parameter is used to protect the PTO motor / spray pump / spinner from over
speeding by someone inadvertently setting the PTO to run at too high a speed on the main
PTO page. The PWM output % means the maximum percentage oil flow that can be sent
out from the valve.
Machine Settings
Low fuel warning – Default 15 litres, can be set as required, fuel tank capacity is 300
litres
Auto input – For headland control the cruise control and rear steering is normally
activated by the green joystick button (sprayer on/off). It is possible to wire in an external
connection so the headland control is activated by a remote switch (e.g. on a fertiliser
spreader shut-off).
Auto record hours – Not currently used

Table of Contents