COMMAND
GROUP
RESPONSE
NUMBER
RESPONSE DESCRIPTION
01 01 OK
01 02 Bad Command Structure
01 03 Empty Library or Bad Range
01 04 Wrong Number of Command Arguments
01 05
Invalid Subcommand
01 06 Invalid Command
01 07 Not Available During Standby (deprecated)
01 08 Requested data not available
01 09 External control command not yet implemented
(possible future implementation)
01 10 Not Available at This Time
01 11 Invalid Security Password
Response Format: ESCX01xx, where xx = Command response
Response 07 has been deprecated due to the new auto-on function. Whenever a valid
command is received (with two exceptions), the system will automatically enter the “on”
mode, if it is in standby. A client may still handle response 07, but it is no longer sent
from the host for any reason.
Response 10 will be sent when a normally valid command is sent to the host, but it
cannot be processed due to the system’s mode. For example, a database play will not be
processed while the system is in setup or options mode, AutoBuilding a changer, etc.
Note that a key press command will never return this response, as even audio transport
keys (play, stop) have alternate functions in various modes.
Unsolicited Status Events
Unsolicited status events can be sent to report the state changes of the McIntosh products.
There are two currently defined message levels: 5 - track changes, and 10 - all (including
1-second playing time updates). Clients are registered at level 5 by default. Clients may
change their message level using the ESCX7002 command. See the control commands
section for instructions on how to resister and unregister for unsolicited status event
levels.
COMMAND
GROUP
EVENT
NUMBER
EVENT DESCRIPTION
02
01 Power status changed. When the system has booted into an off state
you will receive a “RDY” status indicating it is ready to be powered
on and from then on an “OFF” or an “ON “ status.
02
Event Format: ESCX02010010003xxx,
Where xxx = a 3 character string