20
Audyssey
®
Parameter Check
An error message is displayed if the Audyssey Auto
Setup could not be completed due to speaker place-
ment, the measurement environment, etc. If this hap-
pens, check the relevant items, make any necessary
corrective measures, then perform Audyssey Auto
Setup over again.
On-Screen Display
Error Details Corrective Measures
Caution!
No microphone or Speaker
Retry
Check cause of problem!
AUTO SETUP
AUDYSSEY AUTO SETUP
RETURN Cancel
MultEQ XT
The connected setup microphone
is broken, or a device other than
the supplied setup microphone is
connected.
Not all speakers could be detected.
The front L speaker was not prop-
erly detected.
Connect the included setup microphone to
the SETUP MIC jack of this unit.
Check the speaker connections.
Caution!
Ambient noise is too high
or Level is too low
Retry
Check cause of problem!
AUTO SETUP
AUDYSSEY AUTO SETUP
RETURN Cancel
MultEQ XT
There is too much noise in the
room for accurate measurements to
be made.
Speaker or subwoofer sound is too
low for accurate measurements to
be made.
Either turn off any device generating
noise or move it away.
Perform again when the surroundings are
quieter.
Check the speaker installation and the
direction in which the speakers are facing.
Adjust the subwoofer’s volume.
Caution!
Check cause of problem!
Retry
Front R None
AUTO SETUP
AUDYSSEY AUTO SETUP
RETURN Cancel
MultEQ XT
The displayed speaker could not be
detected.
Turn off the power before checking
speaker connections.
Check the connections of the displayed
speaker.
Caution!
Check cause of problem!
Retry
Skip
Front L Phase
AUTO SETUP
AUDYSSEY AUTO SETUP
RETURN Cancel
MultEQ XT
The displayed speaker is connected
with the polarities reversed.
Check the polarities of the displayed
speaker.
For some speakers, this error message
may be displayed even if the speaker is
properly connected. If you are sure the
connection is correct, press to
select “Skip”, then press ENTER.