Air Cooled Chiller
Models:
MAC060/090/120D4
Contents
INSTALLATION, OPERATION & MAINTENANCE MANUAL

Questions and Answers

  • N
    Nathaniel RoseSep 8, 2025
    What does TH1 failure mean on McQuay Chiller?
    • R
      ryan93Sep 8, 2025
      A TH1 failure in your McQuay Chiller might indicate a Comp.1 discharge temperature sensor disconnect. Check the TH1 resistance and replace if necessary. It could also be due to a PCB failure, requiring you to change the PCB.
  • R
    Robert BakerAug 22, 2025
    Why is my McQuay MAC060D4 compressor overloading?
    • D
      Donald WoodsAug 22, 2025
      If your McQuay Chiller's compressor is overloading, it could be due to the compressor running current being too high, which triggers the overload protection. You should check if the current overload setting is correct according to the wiring diagram. Also, verify if the compressor resistance is normal.
  • R
    robertchaseSep 5, 2025
    What to do if McQuay MAC060D4 over heats lower than 2 for 5 minutes?
    • T
      tara53Sep 5, 2025
      If your McQuay Chiller overheats and remains lower than 2 for 5 minutes, it could be due to a broken low pressure/temperature sensor, requiring a replacement. Another potential cause is EXV failure, which also requires replacing the EXV.
  • J
    johnsonjessicaSep 3, 2025
    What causes ambient temperature too high or low in McQuay Chiller?
    • C
      Christian MooreSep 3, 2025
      If the ambient temperature is too high or low in your McQuay Chiller, it could be because the temperature sensor is broken, in which case you should replace it. Alternatively, the temperature may be beyond the operating limit, requiring you to power off the system.
  • K
    Katrina LeeSep 2, 2025
    Why is the EWT/LWT too low in my McQuay MAC060D4 Chiller?
    • C
      carpenterronaldSep 2, 2025
      If the EWT/LWT is too low in your McQuay Chiller, it could be due to the EWT setting being too low. Reset the EWT. It may also be caused by a lack of water flow, leading to a high water temperature difference; in this case, check the hydraulic system. Another potential cause is an electric heater short circuit, which would require changing the electric heater.
  • T
    Thomas ManningAug 31, 2025
    What to do if the pressure differential gauge fails in my McQuay Chiller?
    • K
      Kyle GarnerSep 1, 2025
      A pressure differential gauge failure in your McQuay Chiller can be caused by several factors: the pump selection might be too small, the strainer could be blocked, the hydraulic system may not be adequately vented, the pressure differential gauge itself might be blocked or faulty, the hydraulic system might have too much WPD and is not balanced, or other components in the hydraulic system could be blocked. To address this: * Change the pump if it is too small. * Clean the strainer if it is blocked. * Pump down the system to vent air. * Maintain or change the water pressure differential gauge if it is blocked or faulty. * Optimize the hydraulic system if it has too much WPD and is not balanced. * Check and maintain other components in the hydraulic system for blockages.
  • I
    ilucasAug 30, 2025
    Why is the fan overloading in my McQuay MAC060D4?
    • A
      ayalasamuelAug 30, 2025
      If the fan in your McQuay Chiller is overloading, it could be because the fan running current is too high, triggering the overload protection. Check if the current overload setting is correct according to the wiring diagram. Also, verify if the fan resistance is normal.
  • A
    Alan GordonAug 29, 2025
    What causes a pump overload in McQuay MAC060D4 Chiller?
    • P
      pchavezAug 29, 2025
      If your McQuay Chiller's pump is overloading, it's possible the pump running current is too high, causing the overload protection to activate. Verify the pump current overload setting is correct according to the wiring diagram. Also, check if the pump resistance is normal.
  • L
    Lisa WrightAug 27, 2025
    Why is the discharge temperature too high on my McQuay MAC060D4?
    • C
      christinascottAug 27, 2025
      If the discharge temperature is too high in your McQuay Chiller, it could be due to motor failure, return air short circuit, or a dirty condenser. Also, it can happen if the EWT is too high, or there is a lack of refrigerant or leakage. To solve this, change the fan motor, improve terminal equipment air circulation, and clean the condenser. If the EWT is too high, reset it by service personnel. If there is a lack of refrigerant or leakage, charge refrigerant.
  • M
    Melinda TylerAug 25, 2025
    What causes a low pressure malfunction in McQuay Chiller?
    • C
      cherylwongAug 25, 2025
      A low-pressure malfunction in your McQuay Chiller may be due to a leakage or lack of refrigerant. Check for any leaks and recharge the system. It could also be caused by a PCB low-pressure output failure, in which case you should replace the PCB. Another possible cause is a faulty low-pressure sensor; if this is the case, replace the pressure sensor switch.