TECHNICAL DATA - TABLEAU DES DONNÉES TECHNIQUES
B 360 BV 290E
CERT.
MP5155
Oil-Burning
Industrial Heater
MP5155
Oil-Burning
Industrial Heater
MAX
379000 Btu/h 276300 Btu/h
1950 cfm 1950 cfm
2.74 gal/h 2 gal/h
K-1 Kerosene
No. 1 or No. 2 Fuel Oil
K-1 Kerosene
No. 1 or No. 2 Fuel Oil
27.7 gal 27.7 gal
~120 V (-15%÷10%)
60 Hz
11.4 A 1.4 kW
~120 V (-15%÷10%)
60 Hz
11.4 A 1.4 kW
231 lb 271 lb
2.00 GpH 80°H
DANFOSS
1.50 GpH 80°S
DANFOSS
188 PSI
1300 kPa
13 bar
174 PSI
1200 kPa
12 bar
IMPORTANT: In order to have a correct function you must use an electrical generator in class G3 or more (frequency va-
riation ±1%, tension variation ±2%). The maximum power of electrical generator must be three time the nominal power of device
that you must connect.
FUEL PUM ADJUSTMENT
RÉGLAGE DE LA POMPE À CARBURANT
MODEL
MODÈLE
NOZZLE
PISTOLET
PRESSURE
PRESSION
B 360 DANFOSS 2.00 GpH 80°H 188 PSI 1300 kPa 13 bar
BV 290E DANFOSS 1.50 GpH 80°S 174 PSI 1200 kPa 12 bar