TECHNICAL DATA - TABLEAU DES DONNÉES TECHNIQUES
FUEL PUM ADJUSTMENT
RÉGLAGE DE LA POMPE À CARBURANT
MODEL
MODÈLE
NOZZLE
PISTOLET
PRESSURE
PRESSION
BV 77E DANFOSS 0.40 GpH 80°S 174 PSI 1200 kPa 12 bar
BV 110E DANFOSS 0.65 GpH 80°S 174 PSI 1200 kPa 12 bar
BV 170E DANFOSS 1.00 GpH 80°S 145 PSI 1000 kPa 10 bar
BV 77E BV 110E BV 170E
CERT.
-
MP5155
Oil-Burning
Industrial Heater
MP5155
Oil-Burning
Industrial Heater
MAX
68300 Btu/h 112800 Btu/h 160400 Btu/h
910 cfm 1060 cfm 1060 cfm
0.53 gal/h 0.86 gal/h 1.23 gal/h
K-1 Kerosene
No. 1 or No. 2 Fuel Oil
K-1 Kerosene
No. 1 or No. 2 Fuel Oil
K-1 Kerosene
No. 1 or No. 2 Fuel Oil
9.5 gal 17 gal 17 gal
~120 V (-15%÷10%)
60 Hz
3 A 0.36 kW
~120 V (-15%÷10%)
60 Hz
7.5 A 0.9 kW
~120 V (-15%÷10%)
60 Hz
7.5 A 0.9 kW
73 lb 135 lb 148 lb
0.40 GpH 80°S
DANFOSS
0.65 US GpH 80°S
DANFOSS
1.00 US GpH 80°S
DANFOSS
174 PSI
1200 kPa
12 bar
174 PSI
1200 kPa
12 bar
145 PSI
1000 kPa
10 bar
IMPORTANT: In order to have a correct function you must use an electrical generator in class G3 or more (frequency va-
riation ±1%, tension variation ±2%). The maximum power of electrical generator must be three time the nominal power of device
that you must connect.