EHC-C www.easthigh.com.cn 3
Function Keys
0~9
- Numeric keys for data entry
Unit
- Toggles weight unit of measure
0/Clear
- Press for 4 seconds to clear data or accumulated
values
Enter
- Confirms the operation or saves the data
Print
- Outputs data via the RS232 port
Accu
- Accumulates the current weighed values. Press for 4
seconds to display total accumulated quantities and weight.
Tare
- Tares the weight when the scale is stable
Hi/Lo
-Sets upper and lower check quantity limits
PCWT/SPL -
Enters piece weight calculation mode.
RC.PLU -
Recalls a stored piece weight or tare weight and its
unit of measure
ST.PLU
- Stores a piece weight or tare weight and its unit of
measure
ZERO/ON/OFF
- Powers on the scale. Press for 4 seconds to
power off the scale. In weighing mode, sets the zero point. In
calibration, setup, and other modes, exits the current mode.
Key combinations (Press for 4 seconds)
ZERO/ON/OFF and 0 -
Enters calibration mode
ZERO/ON/OFF and4 -
Enters RS232 parameter setup mode
ZERO/ON/OFF and 1 -
Enters LED brightness setup mode
ZERO/ON/OFF and5 -
Enters date and time setup mode
ZERO/ON/OFF and 2 -
Enters auto-off time setup mode
ZERO/ON/OFF and6 -
Enters ID setup mode
ZERO/ON/OFF and 3 -
Enters
display ACD inner code or working voltage mode
ZERO/ON/OFF and7 -
Enters business name setup mode
4. OPERATIONS
Normal Weighing Mode
1. Place the scale on a flat, stable surface. Level the scale using the leveling bubble at the lower left side of the display.
2. With the weighing platter empty, turn on power switch (located underneath on the left-hand side of the scale). Due to
the high resolution of this scale, allow 10 minutes for the scale to warm up before use for optimum results.
3. Press the ZERO/ON/OFF key to power on the scale. The self-check will run and the scale will display a zero reading.
The scale is now ready for weighing.
4. Note: If the scale does not zero, an error code will be displayed. See Troubleshooting to resolve. (page 13)
5. To change the weighing unit of measure, press the Unit key to toggle between kg and lb.
6. Set the tare weight if desired.
7. Place objects on the scale platter and read the weight on the indicator.
8. Print data if desired. (page 9)
9. When finished weighing, press the ZERO/ON/OFF key for 4 seconds to power off the scale.
Setting the Tare Weight
This scale allows for both a manually entered pre-set tare weight, as well as a “weighed” tare weight.
1. To enter a weighed tare:

Related product manuals