Page 22 Micro 19-XD - Operator’s Manual
July 2020Section 9 - Operating Instructions and Function Tests
Emergency Lowering
If the control system fails while the platform is elevated, use the
emergency lowering procedure to safely lower the platform.
Do not climb down the scissor assembly or exit the platform.
The Emergency Lowering System is used to lower the platform in case of
power failure.
Pull the Emergency Lowering Knob to lower the platform.
ART_4986
Emergency
Lowering
Knob
Outdoor/Indoor Switch
Select working environment before using machine.
Turn the switch to outdoors to restrict platform height when working
outdoors.
Turn the switch to indoors to allow unrestricted platform height when
working indoors.
Art_5587
Operation from Ground
Drive and steer functions are not available from the ground controls.
Turn the Key Switch to ground control.
Set the red Emergency Stop buttons to the ON position at both the ground
and platform controls.
Be sure the battery pack is connected before operating the machine.
ART_4987
Check the area above and around the machine for obstructions and
electrical power lines before operating the machine.