Page 17 Micro 26 - Operator’s Manual
March 2019Section 7 - Operating Instructions and Function Tests
Operating Instructions
Check the area above and around the machine for obstructions and
electrical power lines before operating the machine.
Emergency Stop
ART_3353
Push in the red Emergency Stop button to the off position at the ground
controls or the platform controls to stop all machine functions.
If any function operates when either red Emergency Stop button is pushed in,
repair the Emergency Stop function before using the machine.
Emergency Lowering
If the control system fails while the platform is elevated, use the
emergency lowering procedure to safely lower the platform.
Do not climb down the scissor assembly or exit the platform.
ART_5016
Emergency
Lowering
Handle
The Emergency Lowering System is used to lower the platform in case of
power failure.
Pull the Emergency Lowering Handle to lower the platform.
Operation from Ground
ART_5017
Drive and steer functions are not available from the ground controls.
Turn the Key Switch to ground control.
Pull or turn the red Emergency Stop button clockwise to the on position at
both the ground and platform controls.
Be sure the battery pack is connected before operating the machine.
1.
2.
3.
Check the area above and around the machine for obstructions and
electrical power lines before operating the machine.
To Position Platform
ART_5018
Move the up/down toggle switch according to the markings on the control
panel.