MEGABRAS HP80KV User Manual

Default Icon
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the MEGABRAS HP80KV and is the answer not in the manual?

MEGABRAS HP80KV Specifications

General IconGeneral
BrandMEGABRAS
ModelHP80KV
CategoryTest Equipment
LanguageEnglish

Summary

Product Description

Control Panel Functions

Generation Unit Controls

Details the controls and indicators on the high-voltage generation unit of the HP80KV.

Control Unit Overview

Identifies and describes the various connectors, buttons, and indicators on the control unit.

Control Unit Keyboard Functions

Explains the function of each button on the control unit's keyboard for navigation and operation.

Control Unit Display Information

Details the alphanumeric LCD display, showing example information for test parameters and status.

Test Area Safety Requirements

Test Area Safety Conditions

Outlines three essential safety conditions for the test area: Grounding, Distance, and Containment.

Settings and Adjustments

Menu Navigation and Controls

Explains how to navigate the equipment's menu for settings and adjustments using the rotary selector and buttons.

Configuration Menu Options

Details the available menu options for test setup, language selection, general settings, and memory management.

Emergency Stop and Generation Lock

Connecting the HP80KV

Connection Procedures

Step-by-step guide for correctly connecting the equipment units, cables, and power supply for safe operation.

Operating the Equipment

Operational Steps and Test Results

Guides the user through the operational sequence, test execution, and interpretation of test results and indicators.

Display Messages and Status

Setting Up Tests

Manual Test Mode Setup

Manual Mode - Maximum Current Configuration

Configures the maximum current limit for manual mode tests, with options to enable or disable the limit.

Manual Mode - Maximum Voltage Setting

Auto Test Mode Setup

Auto Mode - Test Voltage Configuration

Sets the test voltage for automatic mode, defining the voltage to be applied during the test.

Auto Mode - Dwell Time Configuration

Configures the dwell time for automatic tests, specifying the duration the voltage is applied.

Ramp Test Mode Setup

Ramp Test - Ramp Up Rate Configuration

Sets the voltage ramp-up rate (V/s) for ramp tests, defining how quickly voltage increases.

Ramp Test - Ramp Down Rate Configuration

Ramp Test Results Display

Describes how the ramp test results, including total time and voltage application duration, are displayed.

SVT Step Voltage Test Setup

SVT - Maximum Voltage Setting

Sets the maximum voltage for the Step Voltage Test, defining the target voltage to reach.

SVT - Time Step Configuration

Configures the time interval for each voltage step in the SVT mode, determining the duration per step.

SVT - Step Voltage Increment Configuration

Other Functions

Internal Memory Management

Details the internal memory capacity for storing measured values and advises on data download for safety.

Software and Drivers

USB Driver Installation

Instructions for installing USB drivers required for PC communication with the equipment.

MegaLogg2 Software Functionality

Describes the MegaLogg2 software for synchronizing data, transferring stored data, and generating reports.

Remote Control via Bluetooth

Bluetooth Pairing Procedure

Guides the user through enabling Bluetooth and pairing the Android device with the HP80KV equipment.

Cleaning Instructions

Maintenance and Fuse Replacement

Technical Specifications

Warranty Information