30 
 
1 
P12.12 
Flux-weak
ening 
adjustmen
t 
coefficient 
2 
Flux-weakeni
ng 
adjustment 
coefficient 2 
0~10000 1 3000 × √  ○ 
P12.13 
Flux-weak
ening 
control 
mode 
Flux-weakeni
ng control 
mode 
0~1 1 1 × √  ○ 
P12.14 
Cooling 
fan control 
Fan control 
0: Operate automatically 
1: Fan operates continually during 
power-up 
2: Fan operates based on 
command 
Note: It will keep running for 3 
minutes after power-off 
1 2 × √ × 
P12.18 
Control 
optimizati
on 
parameter
s 1 
Control 
optimization 
parameters 1
0~65536 1 4 × √ × 
P12.19 
Control 
optimizati
on 
parameter
s 2 
Control 
optimization 
parameters 2
0~65536 1 0 × √ × 
Group P13: Multi-stage reference and simple PLC parameters 
P13.00 
Multi-stag
e 
reference 
properties 
setting 
Multi-stage 
reference 
properties 
0: Multi-stage frequency 
reference 1 
2: Multi-stage frequency 
reference 2 
 
1 0 × √ ○ 
P13.01 
Multi-stag
e 
reference 
1 
Multi-stage 
reference 1 
When it is multi-stage frequency: 
0.0%~100.0% corresponds to 
“minimum frequency ~ maximum 
frequency” 
When it is multi-stage closed loop 
reference: 
-100.0%~100.0% corresponds to 
“-10V~+10V” 
0.1% 10.0% × √ ○ 
P13.02 
Multi-stag
e 
reference 
2 
Multi-stage 
reference 2 
0.1% 20.0% × √ ○ 
P13.03 
Multi-stag
e 
reference 
3 
Multi-stage 
reference 3 
0.1% 40.0% × √ ○ 
P13.04 
Multi-stag
e 
reference 
Multi-stage 
reference 4 
0.1% 60.0% × √ ○