85-03-01194 FV48 Page 70
Vent Damper Adjustments
This fireplace is equipped with a vent damper system that can be adjusted using the glass latch tool. Locate damper adjustment
rod above the glass frame in convection chamber at the center. If this fireplace’s vent is terminated horizontally, DO NOT CLOSE
the vent damper completely. Adjust position of damper by judging the flame characteristics after 20 minutes of burn time. If the
flames ghost off burners or if sooting occurs [in LPG units], open the vent damper FULLY and work backwards in increments to
determine the correct damper position for that particular installation.
Look into the convection air
cavity and note the Damper
Position Indicator. Hook glass
latch tool in the hole at the
end of the damper rod, pull
outward about 1/8” and turn
clockwise to close the vent
damper, release. The base of
the damper adjustment rod
has a pointer that indicates
the position of the damper.
4.12 LIGHTING CHECKLIST
Be sure to check these items before final operation of the Fireplace.
All items on "Installation Checklist" must be completed.
Carefully follow all lighting and log installation instructions. Make certain that pilot flame lights immediately and lights both
front and rear burners.
Check for Gas leaks and gas pressures prior to installing facing materials
Fresh batteries are in remote control. Follow “First-Time Lighting Instructions” to synchronize the remote control and
the ignition module.
Air shutter opening 0" to ⅛" natural gas or ¼” to ½” LP gas is checked.
All lighting and log installation instructions were followed.
Burners light immediately and flame runs promptly around rear burner and lights entire burner.
Note: Do not proceed with operation unless burner cycles "on/off" without delays.
Flame is "stable" and does not "lift" off burner. If flame lifts off burner, turn unit off and check that all vent pipes are
"twist locked" and leak proof, the vent cap is "right side up. Do not proceed with operation if flame is "lifting off"
burner.
DO NOT proceed with operation unless burner cycles "on/off" without delays and the flame is "stable" and not "lifting" off
burner after 5 minutes of initial ignition.
Caution: If pilot goes out, be sure to wait a minimum of five minutes before relighting.